Troubleshooting and Manuals
At Pro-Air, we provide our customers with the highest quality and most up-to-date information regarding their products. Below are some documents of interest to help assist you with product information, questions and troubleshooting.
General Manuals
The Basic A/C System Operation
Auto Mini Programing
General Fitting and Clamping Guide
Charge Amounts and Allowances
Compressor Oil Chart
Commercial Product Manual
Early Heater System Fails
Owners Manual for 400 Series Heater
Van Conversion Manual
110/12v Installation
Ford Transit Connect Installation
Troubleshooting
Troubleshooting Guide
Blower Concerns Troubleshooting
Heating and Cooling Troubleshooting
ProAir/ACT System and Electrical Reference
|
Relay Board |
Module Board |
Evaporator |
Condenser |
|
|
System |
Board - Schematic |
Board - Schematic |
EZ-3 |
EZ-4 |
EZ-5 |
EZ-6 |
EZ-9 |
EZ-91 |
CS-2 |
CS-3 |
CR-2 |
CR-3 |
CR-4 |
OEM |
Tie-In |
Max |
ACT-30T |
01 000 587 - 40 000 443 |
67 000 125 , 40 000 694 |
X |
|
|
|
|
|
|
|
|
|
|
X |
X |
|
ACT-3523DM |
01 000 630(2) OR 821(2) - 40 000 401(2) |
67 000 125,67 000 128 - 40 000 527 |
X |
|
X |
|
|
|
X |
X |
|
|
|
|
|
X(2) |
ACT-35CR4DM |
01 000 630(2) OR 821(2) - 40 000 401(2) |
67 000 125, 67 000 127 - 40 000 527 |
X |
|
X |
|
|
|
|
|
|
|
X |
|
|
X(2) |
ACT-3523HD |
01 000 630(2) OR 821(2) - 40 000 401 & 403 |
67 000 125, 67 000 128 - 40 000 527 & 40 000 528 |
X |
|
X |
|
|
|
X |
X |
|
|
|
|
X |
X |
ACT-35CR4HD |
01 000 630(2) OR 821(2) - 40 000 401 & 403 |
67 000 125, 67 000 127 - 40 000 527 & 40 000 528 |
X |
|
X |
|
|
|
|
|
|
|
X |
|
X |
X |
ACT-35HD |
01 000 630 OR 821 - 40 000 401 |
67 000 128 - 40 000 527 |
X |
|
|
|
|
|
X |
|
|
|
|
|
|
X |
ACT-3CR2-HD |
01 000 630 OR 821 - 40 000 401 |
67 000 125 - 40 000 527 |
X |
|
|
|
|
|
|
|
X |
|
|
|
|
X |
ACT-35T |
01 000 630 OR 821 - 40 000 403 |
67 000 128 - 40 000 528 |
X |
|
|
|
|
|
X |
|
|
|
|
|
X |
|
ACT-40HD |
01 000 630 OR 821 - 40 000 401 |
67 000 125 - 40 000 527 |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
X |
ACT-40T |
01 000 630 OR 821 - 40 000 403 |
67 000 125 - 40 000 528 |
|
X |
|
|
|
|
X |
|
|
|
|
|
X |
|
ACT-45HD |
01 000 630 OR 821 - 40 000 401 |
67 000 127 - 40 000 527 |
|
|
X |
|
|
|
|
|
X |
|
|
|
|
X |
ACT-50HD |
01 000 630 OR 821 - 40 000 401 |
67 000 128 - 40 000 527 |
|
|
X |
|
|
|
|
X |
|
|
|
|
|
X |
ACT-50T |
01 000 630 OR 821 - 40 000 403 |
67 000 128 - 40 000 528 |
|
|
X |
|
|
|
|
X |
|
|
|
|
X |
|
ACT-6633DM |
01 000 630(2) OR 821(2) - 40 000 401(2) |
67 000 128(2) - 40 000 527(2) |
|
|
|
X(2) |
|
|
|
X(2) |
|
|
|
|
|
X(2) |
ACT-66CR4DM |
01 000 630(2) OR 821(2) - 40 000 401(2) |
67 000 127(2) - 40 000 527(2) |
|
|
|
X(2) |
|
|
|
|
|
|
X |
|
|
X(2) |
ACT-6633HD |
01 000 630(2) OR 821(2) - 40 000 401 & 403 |
67 000 128(2) - 40 000 527 & 40 000 528 |
|
|
|
X(2) |
|
|
|
X(2) |
|
|
|
|
X |
X |
ACT-66CR4HD |
01 000 630(2) OR 821(2) - 40 000 401 & 403 |
67 000 127(2) - 40 000 527 & 40 000 528 |
|
|
|
X(2) |
|
|
|
|
|
|
X |
|
X |
X |
ACT-913/21 |
01 000 631 OR 821 - 40 000 400 |
67 000 131 - 40 000 525 |
|
|
|
|
|
X |
|
X |
|
|
|
|
|
X |
ACT-91323/21 |
01 000 630,631 OR 821(2) - 40 000 400 & 403 |
67 000 125, 67 000 131 - 40 000 525 & 40 000 528 |
X |
|
|
|
|
X |
X |
X |
|
|
|
|
X |
X |
ACT-91333HD |
01 000 631 OR 821 - 40 000 400 & 403 |
67 000 126, 67 000 131 - 40 000 525 & 40 000 528 |
X |
|
|
|
|
X |
|
X(2) |
|
|
|
|
X |
X |
ACT-913HD |
01 000 631 OR 821 - 40 000 400 |
67 000 131 - 40 000 525 |
|
|
|
|
|
X |
|
X |
|
|
|
|
|
X |
ACT-91CR3HD |
01 000 631 OR 821 - 40 000 400 |
67 000 131 - 40 000 525 |
|
|
|
|
|
X |
|
|
|
X |
|
|
|
X |
ACT-91533DM |
01 000 630,631 OR 821(2) - 40 000 400 & 401 |
67 000 128, 67 000 131 - 40 000 525 & 40 000 527 |
|
|
X |
|
|
X |
|
X(2) |
|
|
|
|
|
X(2) |
ACT-915CR4DM |
01 000 630,631 OR 821(2) - 40 000 400 & 401 |
67 000 127, 67 000 129 - 40 000 525 & 40 000 527 |
|
|
X |
|
|
X |
|
|
|
|
X |
|
|
X(2) |
ACT-91533HD |
01 000 630,631 OR 821(2) - 40 000 400 & 403 |
67 000 128, 67 000 131 - 40 000 525 & 40 000 528 |
|
|
X |
|
|
X |
|
X(2) |
|
|
|
|
X |
X |
ACT-915CR4HD |
01 000 630,631 OR 821(2) - 40 000 400 & 403 |
67 000 127, 67 000 129 - 40 000 525 & 40 000 528 |
|
|
X |
|
|
X |
|
|
|
|
X |
|
X |
X |
ACT-919133DM |
01 000 631(2) OR 821(2) - 40 000 400(2) |
67 000 131(2) - 40 000 525 |
|
|
|
|
|
X(2) |
|
X(2) |
|
|
|
|
|
X(2) |
ACT-9191CR4DM |
01 000 631(2) OR 821(2) - 40 000 400(2) |
67 000 129(2) - 40 000 525 |
|
|
|
|
|
X(2) |
|
|
|
|
X |
|
|
X(2) |
ACT-933DM |
01 000 629 OR 822 - 40 000 399 |
67 000 152 - 40 000 634 |
|
|
|
|
X |
|
|
X(2) |
|
|
|
|
|
X(2) |
ACT-9333 |
01 000 587 - 40 000 443 & 01 000 629 OR 822 - 40 000 399 |
67 000 125 , 40 000 694 & 67 000 152 - 40 000 634 |
X |
|
|
|
X |
|
|
X(2) |
|
|
|
|
|
|
ACT-9CR4DM |
01 000 629 OR 822 - 40 000 399 |
67 000 152 - 40 000 636 |
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X(2) |
ACT-933HD |
01 000 629 OR 822 - 40 000 404 |
67 000 151 - 40 000 633 |
|
|
|
|
X |
|
|
X(2) |
|
|
|
|
X |
X |
ACT-9CR4HD |
01 000 629 OR 822 - 40 000 399 |
67 000 151 - 40 000 635 |
|
|
|
|
X |
|
|
|
|
|
X |
|
X |
X |
Sprinter Installation Instructions
Booster Pump, Condenser Relay, Drier, Water Valve (EZ5) || Booster Pump, Condenser Relay, Drier, Water Valve (560)
Compressor
Condenser 109 - Single Wheel || Condenser 110 - Single Wheel || Condenser 110 - Dual Wheel
Evaporator Standard (560) || Evaporator Extended (560)
Evaporator Standard (EZ5) || Evaporator Extended (EZ5)
Plumbing and Electrical - Digital (560) ll Plumbing and Electrical - Rotary (560)
Plumbing and Electrical - Digital (EZ5) ll Plumbing and Electrical - Rotary (EZ5)
Nissan NV Installation Instructions
Nissan NV, Tie-In (1of1) |
Nissan NV Tie-In |
Nissan NV, Super Tie-in (4of4) |
Super Tie-In Plumbing and Electrical
Super Tie-In Evaporator Mounting
Super Tie-In Condenser Mounting
Super Tie-In BP, CR, Drier, WV Mounting
|
Nissan NV, Max (6of6) |
Max Plubing and Electrical
Max Evaporator Mounting
Max Condenser Mounting
Max Compressor, 2982 2012 V6 4.02 Liter
Max Compressor, 2883 2012 V8 5.6 Liter
Max BP, CR, Drier, WV Mounting
|
MV-1 Installation Instructions